My Assets
Foley HVAC
Foley, AL · 3 nodes · Heat pump system
LOADING
—
DELTA T (°F)
Control Signals
R—
Y—
S—
CC—
DT—
V—
O—
W—
Temperatures
SUPPLY DUCT—
RETURN DUCT—
BEDROOM—
AMBIENT (API)—
AMBIENT Δ—
Foley AL — Weather
HUMIDITY—
FEELS LIKE—
CONDITIONS—
WIND—
Diagnostics
DELTA T STATUS—
CYCLE TIME—
DEFROST—
MIN ΔT MET—
AIR HANDLER
—
CONDENSER
—
INSIDE SENSOR
—
Customers
+ ADD CUSTOMER
Loading...
Alert Configuration
+ NEW ALERT
Loading alerts...
Customer Details ✕
ACCOUNT ACTIONS
Compressor Start Sequence
Foley HVAC · Real-time · Updates automatically
CHECKING...
Waiting for live data from your system...
Power Source
Transformer
—
Connection Point
Wirenut #1
Flood Protection Switch
Float Switch · r
—
Connection Point
Wirenut #2
Thermostat Power
R Terminal
—
Thermostat
T-stat Logic
—
Cooling Request Sent
Y Terminal (T-stat Out)
—
Connection Point
Wirenut #3 · Air Handler
Connection Point
Wirenut #4 · Condenser Entry
Cooling Signal Received at Unit
Y Terminal · Logic Board · y
—
Safety Check Passed
Safety Circuit · HPS / LPS / Thermal · s
—
Compressor Switch
Contactor Coil · cc
—
Return Path Connection
Wirenut #5 · Condenser Return
Return Path Connection
Wirenut #6 · Air Handler Return
Circuit Complete
Transformer Common · Return
—
Predictive Analysis
Foley HVAC · Performance envelope · Trend analysis · Anomaly detection
—
VALID CYCLES
Clean cool-mode cycles with heat index data · defrost excluded
—
R² — HEAT INDEX vs DELTA T
Strength of relationship between outdoor conditions and system performance · approaches 1.0 as formula converges
—
BASELINE STATUS
BUILDING → PROVISIONAL → ESTABLISHED → STRONG → CONVERGED
—
PERFORMANCE SLOPE (ΔT/°HI)
How much delta T drops per degree of heat index rise · negative = system works harder in heat
—
SYSTEM EFFICIENCY INDEX
Current performance vs model baseline · 1.0 = exactly as expected · below 0.85 = investigate
—
LIVE DELTA T
Current supply vs return temperature difference from live WebSocket data
—
MODEL EXPECTED ΔT
What the formula predicts this unit should produce at current heat index conditions
NOT INSTALLED
CAPACITOR HEALTH ⓘ
CT clamp measurement · Xc=1/(2πfC) · trending reactive current ratio detects failing capacitors · single-phase required
PENDING
TREND FORECAST ⓘ
Projects days until SEI crosses service threshold · requires converged baseline + 14 days SEI history
HEAT INDEX vs DELTA T
Each dot = one compressor cycle · Line = performance envelope · Cool mode only
HEAT INDEX vs SUPPLY TEMP
Supply air temperature at peak delta T · Flat line = consistent delivery
R² CONVERGENCE — FORMULA BUILDING OVER TIME
Watch R² climb toward 1.0 as more cycles accumulate · Each point = regression recalculated on all cycles up to that point
MOCK DATA
START CAPACITOR HEALTH
Peak inrush current ratio · Sampled first 500ms after CC closes · CT clamp not installed — simulated data shown
MOCK DATA
RUN CAPACITOR HEALTH
Steady-state RMS current ratio · Sampled after 60s runtime · CT clamp not installed — simulated data shown
SAVED PERFORMANCE FORMULAS
LOADING...
Reset after a service call to start fresh accumulation